Specifications
Inputs Norma 6003 3 Voltage + 3 Current Norma 6003+ 3 Voltage + 3 Current + 1 Motor Norma 6004 4 Voltage + 4 Current Norma 6004+ 4 Voltage + 4 Current + 1 Motor Sample rate 200ks/s Measurement update rate 100ms, 200ms, 500ms, 1s Dimensions (H * W * L) 298mm x 215m x 96mm Weight 3.5 kg (7.7 lbs) Display 5.7 inch, TFT LCD, 640×480 Operating temperature -10 °C to +50 °C Storage temperature -30 °C to +60 °C Operating humidity Non-condensing (< 10 °C )
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)Operating altitude 2000m Storage altitude 12000m Ingress protection IP 50 (Terminals mated) according to IEC 60529: Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 VEMC IEC 61326-1: Industrial
IEC 61326-2-2Warranty 1 Year Communication Interface USB/RS485 Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments) PC Software Fluke Power Analyzer software Storage Capacity 32GB Data trend storage rate As per display rate Main Function Meter, Scope, Harmonic, Phasor, Trend Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function Electrical Specifications Voltage Range 10 V, 100 V, 1000 V Crest Factor CF ≤ 2 Maximum Voltage 10 % overload Input Impedance 2M Ω/10pF (Typical) Temperature Coefficient 0.05 * (Spec)/k Bandwidth 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz CMRR 120 dB @ 50/60 Hz Accuracy (% reading + % range) Range 1000 V 100 V 10 V DC 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2 AC (10Hz to 1kHz) 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2 AC (10kHz) 5 + 0.5 5 + 0.5 5 + 0.5 Current Crest Factor CF ≤ 2 Temperature Coefficient 0.05 x (Spec)/k Overload capacity 10 % overload CMRR 120 dB @ 50/60 Hz Shunt (current input) Measuring Range 0.1 A, 1 A, 10 A Input Impedance 0.025 Ω (Typical) Bandwidth 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz BNC (voltage input) Range 0.1 V, 1 V, 10 V Input Impedance 100k Ω/100pF (Typical) Bandwidth 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz Accuracy (% reading + % range) Range 10 A 1 A 0.1 A 10 V 1 V 0.1 V DC 0.1 + 0.2 0.1 + 0.5 0.1+2 0.1+0.1 0.1+0.2 0.1+1 AC (10Hz to 1kHz) 0.1+0.1 0.1+0.2 0.1+1 0.1+0.1 0.1+0.1 0.1+0.5 AC (10kHz) 5+1 5+1 5+1 5+1 5+1 5+1 Motor Module (Torque and Speed) Voltage Range ± 10 V dc, 10 % overload Voltage Channels 2 Input Impedance 1.1M Ω (Typical) Accuracy at dc 0.1 % range + 0.1 % reading Pulse Channels 3 Pulse Logic High Threshold 2 V (Typical) Pulse Logic Low Threshold 0.8 V (Typical) Maximum Pulse Frequency 100 kHz Motor Module (Torque and Speed) Frequency Accuracy 0.05 % range + 0.05 % reading Harmonics 100 (50Hz/60Hz) Calculation method FFT/Interpolation