Specifications
Range Resolution Accuracy BT510 BT520 BT520ANG BT521 BT521ANG Battery Resistance / Strap Resistance1 3 mΩ 0.001 mΩ 1% + 8 ● ● ● 1% +68 ● ● 30 mΩ 0.01 mΩ 0.8% + 6 ● ● ● 0.8%+12 ● ● 300 mΩ 0.1 mΩ 0.8% + 6 ● ● ● ● ● 3000 mΩ 1 mΩ 0.8% + 6 ● ● ● ● ● VDC 6 V 0.001 V 0.09% + 5 ● ● ● ● ● 60 V 0.01 V 0.09% + 5 ● ● ● ● ● 600 V 0.1 V 0.09% + 5 ● ● ● ● ● 1000 V 1 V 0.09% + 5 ● ● VAC (45 Hz to 500 Hz with 800 Hz filter) 600 V 0.1 V 2% + 10 ● ● ● ● ● Frequency (displayed with VAC and AAC)2 500 Hz 0.1 Hz 0.5% + 8 ● ● ● ● ● AC voltage ripple (20 KHz Max) 600 mV 0.1 mV 3% + 20 ● ● ● ● ● 6000 mV 1 mV 3% + 10 ● ● ● ● ● ADC/AAC (with accessory Fluke i410) 400 A 1 A 3.5% + 2 ● ● Temperature 0°C to 60°C 1°C 2°C (4°F) ● ● Meter mode 999 records for each measurement position with time stamp Sequence mode Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp 1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz.
2. Trigger level VAC: 10 mV, AAC: 10 AMeasurement Modes BT510 BT520 BT521 Resistance (mΩ) ● ● ● Battery voltage ● ● ● Voltage DC ● ● ● Voltage AC and frequency (Hz) ● ● ● Ripple volt ● ● ● Temperature of negative battery post (using BTL21 straight probes) ● DC and AC current (and frequency) ● DMM mode ● ● ● Sequence mode ● ● ● Discharge measurement mode ● ● ● Automatic measurement save ● ● ● Wireless communication ● Memory view ● ● ● General Specifications – Battery Analyzer Size (H x W x D) 22 x 10.3 x 5.8 cm (9 x 4 x 2 in) Weight 850 g (1.9 lb) Screen dimensions 7.7 x 5.6 cm (3 x 2.2 in) Interface USB mini Warranty 3 years General Specifications – BTL20ANG Angled Measurement Probe Long angled probe (overall length) 242.2 cm (95.38 in) Short angled probe (overall length) 216.8 cm (85.38 in) Overall span (coil relaxed) 10.1 cm (4 in) Overall maximum span (coil extended) 109.2 cm (43 in) BTL20ANG probe tip angle 20 degrees from horizontal Environment Specifications Operating temperature 0°C to 40°C Storage temperature -20°C to 50°C Lithium-ion battery charging temperature 0°C to 40°C Operating humidity Non-condensing (10°C) ≤ 80% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) Operating altitude Sea level to 2000 meters Storage altitude Sea level to 12,000 meters IP rating IP40 Radio FCC Class A Vibration requirements MIL-PRF-28800F: Class 2 Drop test requirements 1 meter Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C Safety compliance 600 V CAT III EMC IEC 61326 ROHS China, Europe Protection class 2 Pollution Degree II Battery compliance UN38.3 UL2054 IEC62133 2 G per IEC68-2-26, 25 G, and 29