Specifications
Specifications Range¹ / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 VAccuracy234 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 kHz 2.0% + 3 Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging.
Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.General Specifications LCD w/backlight 3½ digits, 6000 counts, updates 4/sec Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 400 Hours Memory Record up to 65000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient 0.1 X (specified accuracy)/°C (< 18°C or > 28°C) Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C Altitude Operating 2,000 m Storage 12,000 m EMC EN 61326–1:2006 Safety compliance ANSI/ISA 61010–1 / (82.02.01) 3rd edition CAN / CSA–C22.2 No 61010–1–12 3rd edition UL 61010–1 3rd edition IEC/EN 61010–1 2010 Safety rating CAT IV 600 V, CAT III 1000 V Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution Degree 2 Size (HxWxD) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) Weight .22 kg (8 oz) Warranty Three years