Overview
ออกแบบโดยช่างไฟฟ้า ผลงานวิศวกรรมโดย Fluke
มัลติมิเตอร์ True-rms ขนาดกะทัดรัดสำหรับช่างเทคนิคซ่อมบำรุงภาคสนาม Fluke 115 คือทางออกสำหรับการใช้งานด้านการทดสอบไฟฟ้าและอิเล็กทรอนิกส์ที่หลากหลาย
Specifications Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 VAccuracy ± ([% of reading] + [counts]): 0.5% + 2 AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 VAccuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩAccuracy 0.9% + 1 Range/resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% + 2 Diode test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% + 2 Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μFAccuracy 1.9% + 2 Range/resolution > 1000 μF Accuracy 5% + 20% Lo-Z capacitance Range 1 nF to 500 μF Accuracy 10% + 2 typical AC amps True RMS
(45 Hz to 500Hz)Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 AAccuracy 1.5% + 3
20 A overload for 30-seconds maxDC amps Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 AAccuracy 1.0% + 3
20 A overload for 30-seconds maxHz (V or A input)2 Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHzAccuracy 0.1% + 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.General Specifications Maximum voltage between any terminal and earth ground 600 V Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600VDisplay Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10℃ to + 50℃ Storage temperature -40℃ to + 60℃ Battery type 9 volt Alkaline, IEC 6LR61 Battery life 400 hours typical, without backlight Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years